{"id":502,"date":"2015-11-12T18:14:19","date_gmt":"2015-11-12T18:14:19","guid":{"rendered":"http:\/\/emo-iran.com\/en\/?p=502"},"modified":"2020-10-10T04:21:27","modified_gmt":"2020-10-10T04:21:27","slug":"plate-diffuser","status":"publish","type":"post","link":"https:\/\/emo-iran.com\/en\/product\/plate-diffuser\/","title":{"rendered":"Plate diffuser(MF650&#038;1100)"},"content":{"rendered":"<h3 dir=\"ltr\">MEMBRANE PLATE DIFFUSER<\/h3>\n<p dir=\"ltr\">This type is manufactured in two sizes (650mm and 1100mm) .<\/p>\n<p dir=\"ltr\">This model decrease cost of piping and increase efficiency of aeration.<\/p>\n<p dir=\"ltr\"><!--more--><\/p>\n<p dir=\"ltr\">The OXYFLEX &#8211; MF1100 membrane plate diffuser consists of a flat, heavily ribbed and fibreglass-reinforced<br \/>\npolypropylene base plate. The diffuser membrane is secured to the base plate with a two-part frame made of fibreglass-reinforced polypropylene. The high-quality injection-moulded membranes are available in\u00a0The OXYFLEX &#8211; MF1100 has an active flat membrane surface of 0.2 m\u00b2In contrast to the tube diffuser, the entire active surface of the plate diffuser is at a hydraulic level. Even for different\u00a0specific air loads, the entire membrane surface always works evenly.The special design of the OXYFLEX &#8211; MF1100 ensures that there is only a small pressure loss,\u00a0which increases very slightly over the service life of the equipment. As a result, apart from the service life, the efficiency is\u00a0also significantly increased compared to other diffuser types.The OXYFLEX &#8211; MF1100 is characterised by the following superior features:<br \/>\nhighly efficient oxygen transfer\u00a0low and stable pressure loss\u00a0special diffuser design that is adaptable to all conditions<br \/>\neasy cleaning of the membranes resulting in\u00a0low-maintenance operation\u00a0The OXYFLEX &#8211; MF1100 is a highly efficient aeration element, which is predominantly used for\u00a0the oxygen supply of biological waste water treatment plants.\u00a0Due to the availability of the diffuser membranes in both EPDM and TPU materials, the OXYFLEX &#8211; MF1100, which has a highly variable design, can also be flexibly used with regard to different water qualities and<br \/>\ncustomer requirements.\u00a0Of course, the OXYFLEX &#8211; MF1100 can also be operated in intermittent mode.The membranes are perforated individually and specifically for each project in order to achieve the perfect oxygen\u00a0transfer for all requirements. The OXYFLEX &#8211; MF1100 membrane plate diffuser is able to cover a very broad operating\u00a0range of up to 20 \/h for each diffuser ( 100 \/h per m\u00b2 of membrane surface). With the fine-bubble design,specific\u00a0oxygen transfer rates in pure water of more than 30 g O \/( x m ) can be achieved by an area-covering layout and\u00a0appropriate water depths.Actual operating values show that this highly efficient diffuser system is able to achieve standard aeration efficiency\u00a0(SAE), which are significantly above the current DWA-M 229-1 guidelines. For example, an oxygen yield of 5.8 kg O \/kWh\u00a0was demonstrated for a waste water treatment plant size of approx. 28,000 EW. These extremely good SAE are also due\u00a0to the comparatively small pressure loss of the diffusers.\u00a0As an option to fine-bubble aeration, the membrane can also be manufactured for a coarse-bubble version.\u00a0The following diagram shows the example of a result of an oxygen transfer test. The values were measured in a round\u00a0tank with a water depth of 5.0 m, a diffuser blow-in depth of 4.8 m and a coverage of 21%.<\/p>\n<p dir=\"ltr\"><strong>AIR-PULSING: mixing without a mixer<\/strong><\/p>\n<p dir=\"ltr\">The option of the intermittent operating mode means that, in a combined tank with alternating nitrification and\u00a0denitrification phases and for a sufficient coverage by OXYFLEX membrane plate diffusers, the use of a mixer may be<br \/>\nnot necessary (&#8220;Air-Pulsing&#8221; process).\u00a0Any sedimentation of the activated sludge during the denitrification phase is prevented by short-term aeration intervals.\u00a0The required aeration intervals are individually adapted to the respective plant with regard to its specific conditions such\u00a0as the sludge index of the waste water. The aeration time is up to 20 seconds and the process is repeated approximately\u00a0every 10 to 20 minutes depending on the plant type.<\/p>\n<h4 dir=\"ltr\" style=\"text-align: center;\">Oxyflex MF 1100\u00a0overview table<\/h4>\n<table dir=\"ltr\" style=\"height: 429px;\" width=\"819\">\n<tbody>\n<tr>\n<td width=\"197\">Diffuser design<\/td>\n<td width=\"74\">Premium<\/td>\n<td width=\"81\">Max Efficient<\/td>\n<td width=\"93\">High Efficient<\/td>\n<td width=\"93\">Efficient<\/td>\n<td width=\"92\">High Airflow<\/td>\n<td width=\"92\">Max Airflow<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Functional check and leakage check<\/td>\n<td width=\"74\">\n<p style=\"text-align: center;\">4<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"81\">6<\/td>\n<td style=\"text-align: center;\" width=\"93\">10<\/td>\n<td style=\"text-align: center;\" width=\"93\">12<\/td>\n<td style=\"text-align: center;\" width=\"92\">20<\/td>\n<td width=\"92\">\n<p style=\"text-align: center;\">20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Diffuser run-in<\/td>\n<td width=\"74\">\n<p style=\"text-align: center;\">4<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"81\">6<\/td>\n<td style=\"text-align: center;\" width=\"93\">10<\/td>\n<td style=\"text-align: center;\" width=\"93\">12<\/td>\n<td style=\"text-align: center;\" width=\"92\">20<\/td>\n<td width=\"92\">\n<p style=\"text-align: center;\">20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Bobble image<\/td>\n<td width=\"74\">\n<p style=\"text-align: center;\">0.5-4<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"81\">0.5-6<\/td>\n<td style=\"text-align: center;\" width=\"93\">1-10<\/td>\n<td style=\"text-align: center;\" width=\"93\">2-12<\/td>\n<td style=\"text-align: center;\" width=\"92\">3-20<\/td>\n<td width=\"92\">\n<p style=\"text-align: center;\">5-20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Min specific load<\/td>\n<td width=\"74\">\n<p style=\"text-align: center;\">0.5<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"81\">0.5<\/td>\n<td style=\"text-align: center;\" width=\"93\">1<\/td>\n<td style=\"text-align: center;\" width=\"93\">2<\/td>\n<td style=\"text-align: center;\" width=\"92\">3<\/td>\n<td width=\"92\">\n<p style=\"text-align: center;\">5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Nom. Operation range<\/td>\n<td width=\"74\">\n<p style=\"text-align: center;\">1-3<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"81\">2-4<\/td>\n<td style=\"text-align: center;\" width=\"93\">4-8<\/td>\n<td style=\"text-align: center;\" width=\"93\">5-11<\/td>\n<td style=\"text-align: center;\" width=\"92\">5-14<\/td>\n<td width=\"92\">\n<p style=\"text-align: center;\">5-18<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Max continuous specific load<\/td>\n<td width=\"74\">\n<p style=\"text-align: center;\">3.5<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"81\">5<\/td>\n<td style=\"text-align: center;\" width=\"93\">9<\/td>\n<td style=\"text-align: center;\" width=\"93\">12<\/td>\n<td style=\"text-align: center;\" width=\"92\">16<\/td>\n<td width=\"92\">\n<p style=\"text-align: center;\">20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Max short-term specific load (maintenance)<\/td>\n<td width=\"74\">\n<p style=\"text-align: center;\">4.5<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"81\">7<\/td>\n<td style=\"text-align: center;\" width=\"93\">10<\/td>\n<td style=\"text-align: center;\" width=\"93\">14<\/td>\n<td style=\"text-align: center;\" width=\"92\">20<\/td>\n<td width=\"92\">\n<p style=\"text-align: center;\">25<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p dir=\"ltr\" style=\"text-align: center;\"><strong>Oxyflex MF 650 overview table<\/strong><\/p>\n<table dir=\"ltr\" style=\"height: 406px;\" width=\"817\">\n<tbody>\n<tr>\n<td width=\"197\">Diffuser design<\/td>\n<td width=\"81\">\n<p style=\"text-align: center;\">Max Efficient<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"93\">High Efficient<\/td>\n<td width=\"93\">\n<p style=\"text-align: center;\">Efficient<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Functional check and leakage check<\/td>\n<td width=\"81\">\n<p style=\"text-align: center;\">4<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"93\">8<\/td>\n<td width=\"93\">\n<p style=\"text-align: center;\">12<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Diffuser run-in<\/td>\n<td width=\"81\">\n<p style=\"text-align: center;\">4<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"93\">8<\/td>\n<td width=\"93\">\n<p style=\"text-align: center;\">12<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Bobble image<\/td>\n<td width=\"81\">\n<p style=\"text-align: center;\">4<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"93\">8<\/td>\n<td width=\"93\">\n<p style=\"text-align: center;\">12<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Min specific load<\/td>\n<td width=\"81\">\n<p style=\"text-align: center;\">0.5<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"93\">1<\/td>\n<td width=\"93\">\n<p style=\"text-align: center;\">2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Nom. Operation range<\/td>\n<td width=\"81\">\n<p style=\"text-align: center;\">1-4<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"93\">2-6<\/td>\n<td width=\"93\">\n<p style=\"text-align: center;\">3-8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Max continuous specific load<\/td>\n<td width=\"81\">\n<p style=\"text-align: center;\">5<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"93\">8<\/td>\n<td width=\"93\">\n<p style=\"text-align: center;\">12<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"197\">Max short-term specific load (maintenance)<\/td>\n<td width=\"81\">\n<p style=\"text-align: center;\">6<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"93\">10<\/td>\n<td width=\"93\">\n<p style=\"text-align: center;\">14<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>MEMBRANE PLATE DIFFUSER This type is manufactured in two sizes (650mm and 1100mm) . This model decrease cost of piping and increase efficiency of aeration.<\/p>\n","protected":false},"author":1,"featured_media":1733,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[13],"tags":[],"_links":{"self":[{"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/posts\/502"}],"collection":[{"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/comments?post=502"}],"version-history":[{"count":5,"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/posts\/502\/revisions"}],"predecessor-version":[{"id":1686,"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/posts\/502\/revisions\/1686"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/media\/1733"}],"wp:attachment":[{"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/media?parent=502"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/categories?post=502"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/emo-iran.com\/en\/wp-json\/wp\/v2\/tags?post=502"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}